To gain maximum temperature uniformity,
MIFCO LT (Low Temperature) Series Convection Furnaces are designed
with a stainless steel high velocity fan to force air evenly
throughout the load. The fan draws air in from the top of the
stainless steel furnace chamber and blows it over the heating
elements to re-enter the furnace chamber through orifices in the
sides and bottom. The temperature control thermocouple is located
in the heated air stream where it enters the work load chamber;
therefore, the parts being heated can never exceed the control
instrument set point. The furnace is lined with four (4) inches of
the finest high temperature castable insulation for continuous
operation and maximum efficiency.
The work load chamber, re-circulating fan
and fan shaft, and door face are made of chrome nickel, heat
resistant stainless steel. (Furnaces larger than the LTE-1830 do not have the stainless work
chamber.)
Electric heating elements are readily
accessible for replacement or repair.
On our smaller LT furnaces, the instrument
panel is located on the side of the furnace with convenient, eye
level controls. Larger units have their controls mounted in either
free standing or wall mounted, NEMA 1 rated enclosures. Our
Industrial Control packages are standard on all models in addition
to many other instrumentation options.
See
Printable Manual
of this Model